CPP API

Init​

Function: Initialize FSA object

Parameters:

  1. ip: Target actuator IP;
  2. net_recv_mode: Network receive mode, optional YIELD_WAIT (blocking wait) or SPIN_WAIT (spin wait).

Return Value: Status code

Power​

OpenRelay​

Function: Open power control board relay

Parameters:

  1. timeout_ms: Timeout (ms), default is 5ms;
  2. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

CloseRelay​

Function: Close power control board relay

Parameters:

  1. timeout_ms: Timeout (ms), default is 5ms;
  2. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Reboot​

Function: Reboot actuator

Parameters:

  1. timeout_ms: Timeout (ms), default is 5ms;
  2. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Control​

EnableControl​

Function: Enable actuator position/velocity/torque/PD mode

Parameters:

  1. ctrl_mode: Control mode enumeration (position/velocity/torque/PD);
  2. timeout_ms: Timeout (ms), default is 5ms;
  3. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface internally executes the following commands sequentially. Failure of any step will cause the interface to return a status code directly:

  1. Get current position/velocity/current/torque feedback;
  2. Set target position/velocity/current command;
    1. Set target position to current position, feedforward velocity to 0, feedforward current to 0 (if enabling position or PD mode);
    2. Set target velocity to 0, feedforward current to 0 (if enabling velocity mode);
    3. Set target current to 0 (if enabling torque mode).
  3. Enable.

DisableControl​

Function: Disable actuator

Parameters:

  1. timeout_ms: Timeout (ms), default is 5ms;
  2. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

SetPositionNoAck​

Function: Send target position command, feedforward velocity command, feedforward torque command, actuator does not reply

Parameters:

  1. tx_pos: Target position;
  2. tx_vel_ff: Feedforward velocity;
  3. tx_tor_ff: Feedforward torque;
  4. timeout_ms: Timeout (ms), default is 5ms;
  5. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface will convert target position and feedforward velocity from radians to degrees, and convert feedforward torque to current value before sending to the actuator. Please check that the actuator parameter configuration (motor model and reduction ratio) is correct before use.

SetPosition​

Function: Send target position command, feedforward velocity command, feedforward torque command, actuator replies with status

Parameters:

  1. tx_pos: Target position;
  2. tx_vel_ff: Feedforward velocity;
  3. tx_tor_ff: Feedforward torque;
  4. timeout_ms: Timeout (ms), default is 5ms;
  5. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface will convert target position and feedforward velocity from radians to degrees, and convert feedforward torque to current value before sending to the actuator. Please check that the actuator parameter configuration (motor model and reduction ratio) is correct before use.

SetVelocityNoAck​

Function: Send target velocity command, feedforward torque command, actuator does not reply

Parameters:

  1. tx_vel: Target velocity;
  2. tx_tor_ff: Feedforward torque;
  3. timeout_ms: Timeout (ms), default is 5ms;
  4. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface will convert target velocity from radians to degrees, and convert feedforward torque to current value before sending to the actuator. Please check that the actuator parameter configuration (motor model and reduction ratio) is correct before use.

SetVelocity​

Function: Send target velocity command, feedforward torque command, actuator replies with status

Parameters:

  1. tx_vel: Target velocity;
  2. tx_tor_ff: Feedforward torque;
  3. timeout_ms: Timeout (ms), default is 5ms;
  4. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface will convert target velocity from radians to degrees, and convert feedforward torque to current value before sending to the actuator. Please check that the actuator parameter configuration (motor model and reduction ratio) is correct before use.

SetTorqueNoAck​

Function: Send target torque command, actuator does not reply

Parameters:

  1. tx_tor: Target torque;
  2. timeout_ms: Timeout (ms), default is 5ms;
  3. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface will convert target torque to current value before sending to the actuator. Please check that the actuator parameter configuration (motor model and reduction ratio) is correct before use.

SetTorque​

Function: Send target torque command, actuator replies with status

Parameters:

  1. tx_tor: Target torque;
  2. timeout_ms: Timeout (ms), default is 5ms;
  3. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface will convert target torque to current value before sending to the actuator. Please check that the actuator parameter configuration (motor model and reduction ratio) is correct before use.

SetPDPositionVelocityNoAck​

Function: Send target position command, target velocity command, feedforward torque command, actuator does not reply

Parameters:

  1. tx_pos: Target position;
  2. tx_vel: Target velocity;
  3. tx_tor_ff: Feedforward torque;
  4. timeout_ms: Timeout (ms), default is 5ms;
  5. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface will convert target position and target velocity from radians to degrees. PD mode does not need to convert feedforward torque to current value. FSA treats it as feedforward torque by default. Please check that the actuator parameter configuration (motor model and reduction ratio) is correct before use.

SetPDPositionVelocity​

Function: Send target position command, target velocity command, feedforward torque command, actuator replies with status

Parameters:

  1. tx_pos: Target position;
  2. tx_vel: Target velocity;
  3. tx_tor_ff: Feedforward torque;
  4. timeout_ms: Timeout (ms), default is 5ms;
  5. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface will convert target position and target velocity from radians to degrees. PD mode does not need to convert feedforward torque to current value. FSA treats it as feedforward torque by default. Please check that the actuator parameter configuration (motor model and reduction ratio) is correct before use.

State​

GetPVCTTe​

Function: Get actuator feedback position, velocity, current, load torque and electromagnetic torque

Parameters:

  1. rx_pvctte: Store the obtained position, velocity, current, load torque and electromagnetic torque;
  2. timeout_ms: Timeout (ms), default is 5ms;
  3. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface will convert feedback position and feedback velocity from degrees to radians, and convert feedback current to electromagnetic torque. Please check that the actuator parameter configuration (motor model and reduction ratio) is correct before use.

EnableSubscribe​

Function: Enable subscribe mode

Parameters:

  1. tx_subs_config: Subscribe mode configuration;
  2. timeout_ms: Timeout (ms), default is 5ms;
  3. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

GetSubsData​

Function: Get the latest subscription data

Parameters:

  1. subs_data: Store the obtained subscription data;

Return Value: Status code

Note: This interface guarantees that each call returns the latest frame of subscription data and discards cached data frames in the Socket buffer.

GetTempVbus​

Function: Get actuator temperature and bus voltage

Parameters:

  1. rx_temp_vbus: Store the obtained actuator temperature and bus voltage;
  2. timeout_ms: Timeout (ms), default is 5ms;
  3. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Note: This interface internally executes the following commands:

  1. Get actuator temperature;
  2. Get actuator bus voltage.

GetErrCode​

Function: Get actuator error

Parameters:

  1. rx_error: Store the obtained error code array, a total of 8 error codes;
  2. timeout_ms: Timeout (ms), default is 5ms;
  3. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Config​

SetPIDParams​

Function: Set temporary immediately effective (imm) PID parameters

Parameters:

  1. tx_pos_kp: Position loop Kp;
  2. tx_vel_kp: Velocity loop Kp;
  3. tx_vel_ki: Velocity loop Ki;
  4. timeout_ms: Timeout (ms), default is 5ms;
  5. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

GetPIDParams​

Function: Get temporary immediately effective (imm) PID parameters

Parameters:

  1. rx_pid_param: Store the obtained temporary immediately effective (imm) PID parameters;
  2. timeout_ms: Timeout (ms), default is 5ms;
  3. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

SetPDParams​

Function: Set temporary immediately effective (imm) PD parameters

Parameters:

  1. tx_pd_kp: PD loop Kp;
  2. tx_pd_kd: PD loop Kd;
  3. timeout_ms: Timeout (ms), default is 5ms;
  4. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

GetPDParams​

Function: Get temporary immediately effective (imm) PD parameters

Parameters:

  1. rx_pd_param: Store the obtained temporary immediately effective (imm) PD parameters;
  2. timeout_ms: Timeout (ms), default is 5ms;
  3. max_retry: Maximum retry count, default is 0 times.

Return Value: Status code

Advanced​

To be implemented

Status Codes​

Status CodeSUCCESSSDK_VER_NOT_MATCHCTRL_PARAM_ERRINTERFACE_HANDLE_ERRARG_ERRNET_ERRTIMEOUTNET_RXBUF_DATA_ERR
Value0-101-102-201-202-301-302-303
MeaningOperation successfulSDK version mismatchActuator configuration parameter errorActuator object not initializedInvalid interface parameterNetwork errorNetwork receive timeoutNetwork receive buffer data does not match sent command
Possible Cause/Actuator firmware version too low or SDK dynamic library and header file version mismatchModel and version number not obtained successfullyInit function not executedParameters passed to interface do not meet requirementsFSA network for corresponding IP is disconnectedWaiting time for receiving actuator return data exceeds specified timeoutReceived system socket input buffer previous frames cause command mismatch